Aqua Master Tools P700 PRO2, pH and EC/CF/PPM metre and thermometer
Code: 39609Related products
Product detailed description
Aqua Master Tools P700 PRO2 is a combined metre for growers who mix solution regularly and want all values at once. On one large display you can read pH, EC, CF, PPM and temperature, so you do not need to switch between two pens or recalculate anything - it is suitable for mixing nutrient solution, in hydroponics and for checking water in a swimming pool, hot tub or pond.
What the P700 PRO2 measures
- pH in the range 0.0 to 14.0 pH
- EC in the range 0.0 to 19.9 mS/cm
- CF in the range 0.0 to 199 CF
- PPM in the range 0 to 1999 PPM
- temperature in the range 0.0 to 50 °C
You switch between EC, CF and PPM with the MODE button, and between Celsius and Fahrenheit with the C/F button. You therefore read directly the unit in which your dosing chart is written. The conversion between EC and CF is fixed (CF = EC in mS/cm times 10), but with PPM always watch the scale - the same EC gives a different number on the 500 scale than on the 700 scale.
Complete set straight out of the box
You do not need to buy anything else to start measuring. The package includes a metre with an integrated rechargeable battery, a pH electrode, an EC electrode and a 6 V DC power adapter with instructions. The metre comes calibrated, so you can take your first measurements within a few minutes of unpacking.
How to use it
Plug the power supply into the socket and the connector into the device, connect the pH and EC electrodes, remove their protective caps and switch the metre on. Then immerse the electrodes in the measured liquid and stir gently until the reading stabilises.
After measuring, switch the metre off, rinse the electrodes with tap water - this reduces the transfer of residues from one solution to another - and return them to their protective caps. If you leave the electrodes permanently in the tank for continuous monitoring, regularly check whether limescale, salts or biofilm are building up on them and clean them in time, or use Cleaner D cleaning solution.
Calibration and probe care
The pH section is calibrated in two points with pH 4.0 and 7.0 solutions, conductivity in one point - Aqua Master Tools works with the EC 1.413 standard and can also be verified with 3.0 and 12.88 EC solutions. The basic equipment therefore includes pH 4 calibration solution, pH 7 and EC 1.413. Repeat calibration roughly once a month; the device has a calibration indicator that will remind you. Store the glass pH probe in KCl storage solution and never let it dry out.
When only one part of the measurement reaches the end of its life, you replace it separately: there is a replacement P700 pH probe and a replacement P700 EC electrode. Each has its own input on the device, so you will not confuse them when connecting. Always order the electrode intended specifically for the P700 PRO2 model - Aqua Master Tools electrodes are tied to a specific metre and a probe from another model may not fit.
Specifications
- pH range: 0.0 to 14.0 pH
- EC range: 0.0 to 19.9 mS/cm
- CF range: 0.0 to 199 CF
- PPM range: 0 to 1999 PPM
- Temperature range: 0.0 to 50 °C
- Resolution: pH 0.1 pH, EC 0.1 mS/cm, CF 0.1 CF, PPM 10 PPM, temperature 0.1 °C
- Accuracy: pH ±0.1 pH, EC/CF/PPM ±2 % F.S., temperature ±1.0 °C
- Automatic temperature compensation in the range 0 to 50 °C
- Calibration: pH two-point 4.0 and 7.0; EC one-point with 1.4, 3.0 and 12.88 EC solutions
- Calibration reminder: after one month
- Electrodes: separate pH and EC electrode, both replaceable
- Replacement electrodes: pH with BNC connector, EC with Large PIN connector
- Power supply: 6 V DC adapter with integrated rechargeable battery and status indicator
- Protection rating: metre IP65, electrodes IP67
- Dimensions: 200 x 140 x 34 mm, weight 418 g
- Manufacturer's warranty: 1 year for the device, 6 months for the pH electrode
- Package contents: metre with rechargeable battery, pH electrode, EC electrode, 6 V DC adapter, instructions
Aqua Master Tools gives 6 months on the pH electrode and one year on the body of the device. Rinse the electrode after each measurement and keep it in KCl storage solution between measurements.
Why choose the P700 PRO2
Compared with a cheap pen, you get three extra things. A large display where you can see all values at once and do not need to keep switching. Separate electrodes that you replace individually instead of the whole device - a worn pH probe does not mean a new metre. And a rechargeable battery with adapter, so you do not have to deal with finding cells in the middle of watering. If you measure daily, it pays off in peace of mind and dosing accuracy.
Frequently asked questions
What do I find in the P700 PRO2 package?
The box contains a metre with an integrated rechargeable battery, a pH electrode, an EC electrode and a 6 V DC power adapter together with instructions. You therefore do not need to buy any probe to start measuring. Additional recommended equipment includes pH 4.0, pH 7.0 and EC 1.413 calibration solutions and KCl storage solution for storing the pH probe.
Is the P700 PRO2 suitable for measuring directly in substrate?
The P700 PRO2 is a combined metre for liquids - nutrient solution in a tank, water in a swimming pool, hot tub or pond. For moist substrate, use a device with a substrate electrode; with Aqua Master Tools, for example, the S300 series for pH and E300 for EC. If you need to measure both, count on two devices.
Which solutions is the P700 PRO2 calibrated with?
pH is calibrated in two points with pH 4.0 and 7.0 solutions, conductivity in one point with the Aqua Master Tools EC 1.413 standard; the device also accepts 3.0 and 12.88 EC solutions for checking higher values. Repeat calibration approximately once a month and always after replacing the electrode. Calibration solutions in 20 ml sachets are for single use.
Does only the electrode change on the P700 PRO2, or the whole metre?
Only the electrode. The P700 PRO2 has separate pH and EC probes, and we list each as its own spare part: the pH probe with BNC connector and the EC electrode with Large PIN connector. Aqua Master Tools covers the device with a one-year warranty and the pH electrode with six months. After replacement, calibrate the metre again with pH 4.0 and 7.0 solutions, and conductivity with the EC 1.413 standard.
Additional parameters
| Category: | Measuring Sets |
|---|---|
| EAN: | 7061116080518 |
| PFHGX: | Levné, Best-selling, Doporučené, High-quality, Značkové, Základní |
| blogpost How to Use Calibration Solutions and pH Meters?: | /jak-pouzivat-kalibracni-roztoky-a-ph-metry/ |
| blogpost How to Measure Conductivity (EC) Correctly?: | /jak-na-spravne-mereni-vodivosti--ec/ |
| blogpost Aqua Master Tools - digital measuring instruments from the Netherlands: | /aqua-master-tools-digitalni-merici-pristroje-z-holandska/ |