AC Infinity Inline Duct Silencer, 100 mm

Code: AC-DSA4
€63,09 €52,14 excl. VAT Measure price:
In Stock
The AC Infinity DSA4 aluminium silencer (100 mm) fits into a duct run and reduces fan airflow noise by up to 50% with wave-shaped neoprene foam. Airflow capacity is maintained, and it works for both intake and extract. Galvanised steel body with reversible stainless steel flanges.

Detailed information

Product detailed description

Airflow silencer in a 100 mm duct run

AC Infinity Inline Duct Silencer DSA4 is an aluminium/stainless steel silencer (muffler) inserted directly into a ventilation duct with a diameter of 4" – typically between an inline fan and another duct section. Unlike a coupling, which reduces vibrations at just one joint, the DSA4 reduces airflow noise (whoosh) along its entire installed length.

How the silencing works

Inside the body is neoprene foam in a wave crest (wave crest / egg crate) shape, which absorbs sound waves created by fan vibrations and airflow. It reduces fan noise by up to 50% while maintaining airflow capacity – the silencer works for both intake and extract. Two aluminium/stainless steel flanges further absorb vibrations at the connection point.

Construction

  • Model: AC-DSA4
  • Duct opening diameter: 4"
  • Overall dimensions: 38.0 x 17.7 cm
  • Flange length: 3.8 cm
  • Weight: 2.30 lb
  • Flange material: stainless steel, reversible on both sides
  • Shell material: galvanised steel
  • Filling material: neoprene foam
  • Noise reduction: up to 50%

Where to install it in a 100 mm duct

The silencer can be positioned anywhere in the ventilation chain, typically between the fan and the duct. It can be used in grow tents, hydroponic grow rooms, AV/server rooms, cabinet cooling systems and bathroom ventilation. Combine it with other components with a diameter of 4":

Frequently asked questions

How does the DSA4 differ from a coupling (Noise Reduction Clamp)?
The DSA4 is a separate silencer that reduces airflow noise in the duct run by up to 50%. The RCA4 coupling, on the other hand, seals and reduces vibrations at just one specific joint between two components.

Where is the silencer installed?
Anywhere in the ventilation chain, most commonly between the fan and the duct. It works for both intake and extract.

Does the silencer restrict airflow?
No, the foam filling reduces airflow noise while airflow capacity remains unchanged.

Discussion

Be the first who will post an article to this item!

Only registered users can submit posts. Please log in or sign up.

Do not fill out this field